GST : 24ADPPT4320E1ZM

call images

Call us

08045475747

Insulation Press Paper

Insulation Press Paper
Insulation Press Paper

Insulation Press Paper Specification

  • Thermal Conductivity
  • 0.20 W/mK
  • Elongation
  • 2.0% (at break)
  • Width
  • up to 1200 mm
  • Length
  • Standard roll length 100 meters (customizable)
  • Shelf Life
  • 24 months under proper storage
  • Operating Temperature
  • Up to 105C
  • Density
  • 1.1 Gram per cubic centimeter(g/cm3)
  • Thickness
  • 0.2 mm to 1 mm
  • Product Type
  • Insulation Press Paper
  • Application
  • Used for electrical insulation in transformers, capacitors, electric motors, switchgears and other electrical apparatuses.
  • Material
  • High grade pure cellulose (wood pulp) paper
  • Rated Voltage
  • Up to 36 kV
  • Tensile Strength
  • Greater than 50 N/15mm
  • Function
  • Electrical insulation & mechanical protection
  • Heat Resistance
  • Class A (105C as per IEC Standard)
  • Paper Core
  • 76 mm diameter
  • Color
  • Brown
 
 

About Insulation Press Paper

AIP offer Electrical Insulation Press paper of various type.

Electrical Insulation Paper is manufacture from Pure wood pulp. Insulation paper is applied as Layer insulation, Barrier insulation, Slot insulation in transformer,Dimmer,Variable transformer, electrical motor & wire covering.

We are suppying Insulation paper in Roll form & Slit size as per specific requirement. Slit paper is save time & wastage of material.

Colour       :Natural (Undyed) /Black /Greay

Thickness  : Insulation Paper  5/7/10/15/20 Mil

                     Pressphan sheet 20/3/40/60/80 Mil

Roll Size     : 40 Inch

Slit size       : 15 mm and above

 



Superior Electrical Insulation

Engineered to provide outstanding dielectric strength exceeding 6 kV/mm, this press paper ensures dependable insulation for high-voltage equipment. Its uniform surface finish and strong chemical resistance make it a trusted choice for maintaining safety and performance in transformers, capacitors, and electric motors, minimizing risk of electrical breakdowns.


Exceptional Chemical and Mechanical Properties

Designed for longevity, Insulation Press Paper resists degradation from mineral and transformer oils, featuring a low oil absorption rate to retain its structural integrity over time. With impressive tensile strength greater than 50 N/15mm and 2.0% elongation at break, it safeguards electrical apparatuses from mechanical stresses and environmental impacts.


Customizable and Reliable for Diverse Applications

Supplied in widths up to 1200 mm, with thickness options between 0.2 mm and 1 mm, and customizable roll lengths, this insulation paper adapts to various industrial needs. Its versatility and consistent quality make it highly suitable for manufacturers and service providers across India involved in electrical insulation solutions.

FAQs of Insulation Press Paper:


Q: How is Insulation Press Paper used in electrical equipment?

A: Insulation Press Paper acts as a protective barrier in electrical equipment like transformers, capacitors, electric motors, and switchgears. It separates conducting parts, prevents electrical leakage, and protects components from mechanical stresses and heat.

Q: What are the benefits of its low oil absorption and chemical resistance?

A: Low oil absorption and good resistance to mineral and transformer oils ensure the press paper maintains its insulating and mechanical properties, prolonging its lifespan and enhancing safety even in harsh operational environments.

Q: When should Insulation Press Paper be replaced in electrical apparatuses?

A: Replacement is advised at the end of its 24-month shelf life or if physical damage, reduced insulation strength, or oil saturation is observed during routine maintenance checks.

Q: Where can Insulation Press Paper be sourced in India?

A: It is available from leading exporters, manufacturers, suppliers, and service providers across India, offering both standard and customizable dimensions to match specific application requirements.

Q: What is the recommended operating temperature for optimal performance?

A: For best results, Insulation Press Paper should be used in environments where the temperature does not exceed 105C, aligning with Class A thermal resistance as per IEC standards.

Q: How can the product dimensions be tailored to specific needs?

A: The paper is supplied in standard rolls of 100 meters and widths up to 1200 mm, but length and thickness options (0.21 mm) can be customized upon request to fit different industrial applications.

Q: What process ensures the superior quality of the press paper?

A: Produced from high-grade pure cellulose (wood pulp) using advanced papermaking techniques, the process guarantees uniform density, exceptional dielectric properties, and consistent surface finish, meeting stringent industry standards for electrical insulation.

Tell us about your requirement